ABB

ABB · 722936543498

Cầu dao cắt tải ABB OTM1250E4M230C (1SCA115367R1001)

Sẵn hàngBảo hành: 1 nămXuất xứ: -
Liên hệ
Mã sản phẩm
722936543498
Model
OTM1250E4M230C
Mã nội bộ
ABB - OTM1250E4M230C
Hãng sản xuất
ABB
  • Rated Operational Current AC-21A (Ie): (380 ... 415 V) 1250 A (500 V) 1250 A (690 V) 1250 A (1000 V AC) 1250 A
  • (380 ... 415 V) 1250 A
  • (500 V) 1250 A
  • (690 V) 1250 A
  • (1000 V AC) 1250 A
  • Rated Operational Current AC-22A (Ie): (380 ... 415 V) 1250 A (500 V) 1250 A (690 V) 1250 A
Số lượng
Gọi tư vấn
  • Rated Operational Current AC-21A (Ie):
    • (380 ... 415 V) 1250 A
    • (500 V) 1250 A
    • (690 V) 1250 A
    • (1000 V AC) 1250 A
  • Rated Operational Current AC-22A (Ie):
    • (380 ... 415 V) 1250 A
    • (500 V) 1250 A
    • (690 V) 1250 A
  • Rated Operational Current AC-23A (Ie):
    • (380 ... 415 V) 1250 A
    • (500 V) 1250 A
    • (690 V) 1250 A
  • Rated Operational Power AC-23A (Pe):
    • (400 ... 415 V) 710 kW
    • (500 V) 900 kW
    • (690 V) 1200 kW
  • Conventional Free-air Thermal Current (Ith):q = 40 °C 1250 A
  • Conventional Thermal Current (Ithe):Fully Enclosed 1250 A
  • Rated Impulse Withstand Voltage (Uimp):12 kV
  • Rated Insulation Voltage (Ui):acc. to IEC/EN 60664-1 1000 V
  • Rated Operational Voltage:Main Circuit 1000 V
  • Rated Short-Circuit Making Capacity (Icm):(690 V) 92 kA
  • Rated Short-time Withstand Current Low Voltage (Icw):for 1 s 50 kA
  • Rated Conditional Short-Circuit Current (Inc):
    • (1250 A fuse, 415 V) 80 kA
    • (1250 A fuse, 500 V) 100 kA
  • Motor Operational Voltage:220 ... 240 V AC